Skip to content

abnt_codi ABNT CODI

The ABNT CODI is an old energy meter standard used in Brazil.

This code interprets the end user serial output existent in the energy meter. That output externalizes its data blinking an LED as a serial protocol at the baudrate of 110 BPS and uses 8 octets:

OctetBitsDescription
0010-7Number of seconds to the end of current active demand (LSB)
0020-3 4 5 6 7Number of seconds to the end of current active demand (MSB) Bill indicator. It is inverted at each demand replenishment Reactive Interval Indicator. Inverted at end react interval If 1 means the reactive-capacitive is used to calculate UFER If 1 means the reactive-inductive is used to calculate UFER
0030-3 4-5 6 7Current seasonal segment: 0001 – tip, 0010 – out of tip, 1000 – reserved Type of charging indicator (flag): 00 – Blue, 01 – Green, 10 – Irrigators, 11 – Other Not used If equal 1 means reactive rate is enabled
0040-7Number of pulses for active energy of cur dem interv (LSB)
0050-6 7Number of pulses for active energy of cur dem interv (MSB) Not used
0060-7Number of pulses for reactive energy of cur dem interv (LSB)
0070-6 7Number of pulses for reactive energy of cur dem interv (MSB) Not used
0080-7Inverted bits of _xor from previous octets